Alarm devices for oil, grease and sand separators

With Labkotec oil and grease separator alarms, you’ll know the need to empty the separators in advance. Alarms help your business operate responsibly. Labkotec oil separator alarms are used, for example, at fuel distribution points, on roads and at airports. Our grease separator alarms are used in restaurants. 

Keep the soil and groundwater clean 

The Labkotec oil separator alarm monitors 24/7 and detects if the separator needs to be emptied to prevent oil from being wasted or risking an overflow into the soil or groundwater. Oil separator alarms meet the requirements of EN 858-1 and -2. You can also fulfil your accounting responsibilities to the authorities for the operation and maintenance of the separator and alarm systems. 

ATEX approved separator alarms 

Our separator alarms are approved in accordance with the ATEX Directive 2014/34/EU, IECEx and some of the products are UKEX certified, so they are safe to use even in potentially explosive atmospheres. 

Solar or battery-operated oil separator alarms 

If mains supply is not available at the site, you can select a solar or battery-operated oil separator alarm. You can also use an alarm with an integrated modem to send alarm messages. 

Grease separator alarms for restaurants 

Labkotec grease separator alarms help your company operate responsibly by alerting you when grease separator needs to be emptied. When grease cannot clog drains, you avoid extra costs and odour nuisances. Ensure business continuity and a high level of hygiene in your restaurant operations. 

All alarms in the same LabkoNet cloud service

You can connect the separator alarms to LabkoNet, which is a flexible and easy-to-use remote monitoring system. LabkoNet monitors 24/7 and transmits alarms immediately to the necessary parties regardless of time and place. 

Downloads

OMS-1 oil separator alarm

OMS-1 oil separator alarm

Oil separator alarm device for monitoring oil layer in an oil separator. It indicates when it is time to empty the oil separator.

LabkoNet | ATEX | IECEx | UKEX
Avainlippu
GA-1 grease alarm

GA-1 grease alarm

One sensor grease alarm for monitoring the thickness of the grease layer accumulating in a grease separator. 

LabkoNet
GA-2 grease alarm

GA-2 grease alarm

Two sensor grease alarm for monitoring the thickness of the grease layer accumulating in a grease separator. 

LabkoNet
Avainlippu
idSET-34 oil separator alarm

idSET-34 oil separator alarm

Easy to use oil separator alarm with four relays, one for each sensor and one for faults.

LabkoNet | ATEX | IECEx | UKEX
Avainlippu
idOil-30 oil separator alarm

idOil-30 oil separator alarm

Up to three idOil sensors of any type can be connected polarity-free. Available also with 3G modem and in 12 V DC operation voltage.

LabkoNet | ATEX | IECEx | UKEX
Avainlippu
idOil-D30 oil separator alarm

idOil-D30 oil separator alarm

Control unit an be mounted in an electrical cabinet on DIN rails. Up to three idOil sensors of any type can be connected polarity-free.

LabkoNet | ATEX | IECEx | UKEX
Avainlippu
idOil Solar oil separator alarm

idOil Solar oil separator alarm

Solar-powered alarm and communication unit for monitoring the levels of liquid hydrocarbon, sludge, or high levels in oil and sand separators, in locations where mains power is unavailable.

LabkoNet | ATEX | IECEx | UKEX
Avainlippu
idOil sensors

idOil sensors

idOil sensors are an integral part of the idOil oil separator alarm system and they are to be used with the idOil control units. idOil sensors are digital and polarity free.

ATEX | IECEx | UKEX
Avainlippu
idOil one sensor systems

idOil one sensor systems

With the idOil one sensor alarm system, excessively high liquid levels, oil layer thickness or sludge layer thickness can be monitored. idOil alarm systems are available in complete packages.

LabkoNet | ATEX | IECEx | UKEX
Avainlippu
idOil two sensor systems

idOil two sensor systems

With the idOil two sensor alarm system, excessively high liquid levels, oil layer thickness and sludge layer thickness can be monitored. idOil alarm systems are available in complete packages.

LabkoNet | ATEX | IECEx | UKEX
Avainlippu
idOil three sensor systems

idOil three sensor systems

With the idOil three sensor alarm system, excessively high liquid levels, oil layer thickness and sludge layer thickness can be monitored. idOil alarm systems are available in complete packages.

LabkoNet | ATEX | IECEx | UKEX
Avainlippu
idSET-34 LIQ system package

idSET-34 LIQ system package

System package for detecting high liquid level. High liquid level sensor indicates when the liquid level in the oil separator rises excessively e.g. in an outlet blockage situation.

LabkoNet | ATEX | IECEx | UKEX
Avainlippu
idOil-30 3G oil separator alarm

idOil-30 3G oil separator alarm

Delivered with a 3G data transfer module and antenna. Up to three idOil sensors of any type can be connected polarity-free.

LabkoNet | ATEX | IECEx | UKEX
Avainlippu
SET-1000 and SET/OSK2 Capacitive oil-on-water detector

SET-1000 and SET/OSK2 Capacitive oil-on-water detector

Special version of SET/OS2 equipped with polypropylene floats to detect oil on water in pump sumps. The most common applications are inspection shafts and different kind of basins with altering liquid level.

ATEX | IECEx | UKEX
SET/OSK2 Sensor

SET/OSK2 Sensor

Floating sensor for inspection shafts and different kind of basins with altering liquid level.

ATEX
Avainlippu
Battery Box 10

Battery Box 10

Power supply for idOil-30 Battery and idOil-30 Battery 3G alarm devices.

Avainlippu

The separator must be emptied in every 6 months (EN 858).

The function of an oil separator is easy to check by lifting it up, in which case the sensor should send an alarm. The sensor must be cleaned if it has an oil film when lifting from the separator. Sludge sensor can be tested in a same way.

Very likely the grease sensor is still dirty and needs to be cleaned.

SG1 grease sensor is lifted from separator in to the air, when the sensor should be alarming. HLL-1 grease sensor is put into water, when the sensor should be alarming. SG1 and HLL-1 sensors have to be in a same water for test to succeed.