idOil-30 oil separator alarm
Up to three idOil sensors of any type can be connected polarity-free. Available also with 3G modem and in 12 V DC operation voltage.
Up to three idOil sensors of any type can be connected polarity-free. Available also with 3G modem and in 12 V DC operation voltage.
One-channel level switch can be used as a controller of a level sensor located in potentially explosive atmosphere.
Two-channel level switch that can be used as a controller of a level sensor located in potentially explosive atmosphere.
Special version of SET/OS2 equipped with polypropylene floats to detect oil on water in pump sumps. The most common applications are inspection shafts and different kind of basins with altering liquid level.
Capacitive sensor which can be utilized for leak detection of oil, fuel, chemical, water, etc.
Floating sensor for inspection shafts and different kind of basins with altering liquid level.
Capacitive sensor for e.g. oil/water interface detection.
Special sensor for process mediums causing material build-up on the sensing element.
SET/TSHS2 is a special sensor for viscous liquids. SET/TSH2 is a universal sensor for non-viscous liquids.
Special sensor with adjustable mounting thread for non-viscous liquids having high temperatures. Can be utilized as high or low level detector or for detecting the interface between two liquids.
Reliable full alarm device for cesspool. Control of cesspool is made sure by conductive sensor and harmful overfill can be eliminated.
Dry-boiling guard to be used in closed boiler plants.
Conductive sensor
When the sensor comes into contact with a conducting liquid the control unit will give an alarm.
Compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam.
Versatile inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.
Inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.
Low cost level switches
Test-button activates the buzzer alarm, led lights, and relays, so the sensor function can not be tested with the test button.
Both relays change their status when it alerts, but the relay 1 can be restored by pressing the test button. This should be taken into account if further alarms are connected to the control unit because the system thinks the alarm has been removed if it has been reset with the test button. Relay 2 monitors the alarm status and does not return until the alarm is cleared.
The SET-OELO2 sensor cannot be used in outdoor applications, as humidity can cause unnecessary alarms. Only dry interior is acceptable.
Yes, you can, the instructions can be found in the user manual.